Products / BOD Incubators / Friocell ECO – Low Temperature BOD Incubator
Friocell ECO - Low Temperature BOD Incubator
Patented Forced Air Convection
FRIOCELL® BOD incubators employ a patented forced air convection system that moves air vertically and horizontally inside the chamber to produce precise temperature uniformity. Microprocessor controls ensure accurate temperatures without overshooting the set point and allow for flexible and repeatable cycles for reproducible test conditions. FRIOCELL® BOD incubators are FDA CFR 21 Part 11 compliant when equipped with Warmcomm 4.0F software.
Previous
Next
Specifications
Heat Technology:
Patented Forced Air Convection System
Patented Forced Air Convection System
Chamber Volumes:
55 (4 ft³) • 111 (4 ft³) • 222 (8 ft³) • 404 (14.3 ft³) • 707 (25 ft³) 1212 (43 ft³)
55 (4 ft³) • 111 (4 ft³) • 222 (8 ft³) • 404 (14.3 ft³) • 707 (25 ft³) 1212 (43 ft³)
Temperature Range:
0°C up to 100°C (optional -10°C minimum temp with automatic defrost)
0°C up to 100°C (optional -10°C minimum temp with automatic defrost)
Refrigerant:
R 134a
R 134a
Control System:
Fuzzy Logic enabled ECO digital controller
Fuzzy Logic enabled ECO digital controller
Chamber Construction:
AISI 304 Seamless Stainless Steel with rounded corners
AISI 304 Seamless Stainless Steel with rounded corners
Electrical Data:
230V 50/60Hz
230V 50/60Hz
Certifications:
CE, UL, CSA listed
CE, UL, CSA listed
Chamber Construction
The FRIOCELL® is equipped with a pharmaceutical grade AISI 304 stainless steel chamber with a double wall construction to prolong life expectancy. The inner chamber features a seamless, rounded corner design and is fully removable for easier cleaning and sterilization. The door of the chamber employs a patented 4-point closing system that seals the door to the chamber gasket and enables hands-free opening and closing.
- AISI 304 stainless steel chamber – 316L stainless steel option available
- Double wall chamber construction with 5 layers of insulation for more uniform internal chamber conditions
- Removable inner chamber with seamless, rounded corner design for easier cleaning & sterilization
- 4-point closing system that seals the door to the chamber gasket – automatic or key door lock options availabe, door sensor and alarm option available
- Inner glass door allows viewing into the chamber without affecting internal conditions
- (2″) 50 mm stainless steel port – (1″) 25, (2″) 50, (4″) 100 mm access port options available
- Shelf brackets that do not penetrate the chamber walls – brackets are molded into the inner chamber walls 2.8″ apart
ECO Digitial Controller
FRIOCELL® BOD incubators are equipped with BMT USA’s ECO controller, which utilizes fuzzy logic to assess process data, including operation temperature, chamber size, and other controlled elements. Based on the assessed data, the controller can make continuous adjustments to input values, such as heating intensity or cooling, to optimally regulate internal chamber conditions. With the goal of minimizing the time required to meet set process parameters, FRIOCELL® incubators equipped with the ECO controller can quickly ramp up to the exact temperature set point without overshooting. The result is reduced overall cycle time, power consumption, and recovery times after opening the chamber door(s).
3″ LCD display
Fuzzy logic enabled microprocessor
9 programs each with up to 2 segments for varying loads and parameters up to 99 cycles
Real-time programming and cycling – optional temperature ramping settings
LED indicator of device operation
Constant monitoring of chamber conditions
USB port
RS 232 port
Optional Ethernet port
Delayed heating start & stop function
Digital safety thermostat
Acoustic and digital alarms
Keypad lock
optional integrated data logger for temperature measurement and recording
Heat Technology

BMT Patented Forced Air Convection System
BMT’s patented force air convection system moves air vertically and horizontally inside the chamber for precise temperature uniformity and fast heating and cooling times. The process of heating from the bottom of the chamber to the top mimics natural airflow, allowing for more precise simulation of climatic conditions.
Optional Equipment
Shelving
Stainless steel wire shelf
Stainless steel perforated shelf
Suspension system for hanging samples from the ceiling of the chamber
Construction
Automatic key and door lock
Door sensor and alarm
Adjustable feet or casters with smooth travel and extendable leveling feet
Rolling cart with casters (swiveling/locking and swiveling/leveling)
Window with 3 layers of insulating glass for observation of samples inside the chamber – complimented by interior lighting with mechanical switch
Interior light – heat resistant with mechanical switch or an electronic switch that is automatically activated when the door opens
Waterproof 115V or 230V electrical socket inside the chamber
PT 100 flexible sensor
Stainless steel exterior
Stainless stacking frame for model 111 & 222
316L stainless steel chamber
Functionality
Oxygen control – 1% up to 19%
Inert Gas or aeration connection
Lighting control, VIS
Lighting control, UV
External printer
Compliance
IQ/OQ validation documentation with temperature mapping – DIN 12880
Warmcomm software – FDA CFR 12 Part 11 compliant
Building management monitoring system
Region specific electrical plug